Auburn Golf Course Project Overview

Scope of works

Stormwater is harvested from the surrounding LGA area through diversion into Gross Pollutant Traps (GPT) for pre-screening.

  • Water is harvested from the pump station attached to the GPT’s at a rate of 60L/S to the 2 new 2ML dams onsite
  • From the dams a floating submersible bore pump is hung from a pontoon to deliver water to the existing golf course header tanks.
  • A water treatment system designed and constructed by us will deliver 18l/s to the future irrigation system.
  • A fully integrated PLC will digitally monitor the status of all pumps and components remotely for total system control.

Project gallery

Need Service or Support?

Neverstop are Sydney’s complex water experts. We offer comprehensive after sales service and maintenance to just about anything involving water. Get in touch.